RIVERT and RIVERT smart absolute encoders deliver high precision angle measurements. The absolute position is available immediately after power-on. Depending on the type, the encoders differ in the number of inputs and outputs and available communication interfaces.
Product details RIVERT
- Measuring range 0 ... 360°, accuracy ± 0.044°
- Integrated process value calculations (limit values, linearization)
- Cable connection with cable glands
- 1 analog output with HART® (fully implemented)
- 4 digital outputs (optional)
- 1 status output
- Parallel code outputs (BCD, Gray, binary) on up to 22 digital outputs (optional)
Product details RIVERT smart
- Measuring range 0 ... 360°, accuracy ± 0.044°
- Integrated web server for easy configuration and diagnostics
- Integrated remotely accessible data logger
- Comprehensive process value processing (rake operation, interpolation curves, integration)
- Cable connection with plugs (M23, M12)
- 1 analog output
- 4 digital outputs
- 1 status output
- 1 Modbus RTU interface (master + slave)
- 1 Modbus TCP interface (master + slave)
- 1 Ethernet-100BaseT interface
- IEC-60870-5-104 protocol
- Support of several sensors connected via Modbus RTU+TCP
- Heater (optional)
Technical Data
RIVERT | RIVERT smart | |
Measuring Range | 180° ...+180° | 180° ...+180° |
Measuring Accuracy | 0.044° (1 LSB) | 0.022° (1 LSB) |
Measuring Resolution | 0.044° | 0.0055° |
Outputs
Analogue (4-20mA) | 1 | 1 |
---|---|---|
Status (relays) | 1 (option) | 1 |
Digital (relays) | 21+1 (option) | 4 |
Interfaces
HART | Yes | - |
---|---|---|
RS485 Modbus RTU | - | 1 |
Modbus TCP | - | 1 |
Ethernet 100BaseT | - | 1 |
IEC 60870-5-104 | - | 1 |
Operating Conditions
Protection Class | IP68 | IP67 |
---|---|---|
Operating Temperature | -40°C...+60°C | -20°C...+60°C |
Operating Voltage | 19.2...60VDC | |
Vibration IEC (EN)60068-2-6 | 20ms-2 (10...500Hz) | |
Shock IEC (EN)60068-2-27 | 200ms-2 (12ms) |