Neon Remote Logger - 8 Analog Channels Model 3008

The 3008 Neon Remote Logger NRL is self-contained data logger/RTU with 8 high-resolution analog channels in a compact case which connects to sensors in the field, collects readings from those sensors and transmits the collected data to a central Neon server, or it can be set up to operate as a stand-alone datalogger/RTU. The 3016 can be configured to transmit data via a cellular 2G/3G/4G/LTE network, satellite network like Inmarsat, Iridium SBD or Microsatellite, Wi-Fi network or it can utilise LoRA communication system as its method of sending data from the field to the Neon Server.
  • All Neon data logger/ RTU units routinely collect and log sensor data and periodically connect to a central Neon comms and web server via an IP network using a push data model to upload the logged data.
  • The central Neon server can be cloud-hosted, virtual or physical. The Neon server is offered as a Neon data hosted service using a Unidata Neon server for a monthly fee or customers can purchase a Neon server license and run the Neon software on their own server.
  • The Neon system receives, processes, displays, stores and reports collected data in many ways.
  • The Neon system also can issue control commands based on pre-set algorithms and issue alarms and notifications via several mediums.
  • Alarm setpoints can be set up on the Neon data logger/ RTU units as well as the Neon central server and alarm notifications can be sent via several methods including email and SMS text messages.
  • Alarm triggers can initiate physical actions in the field such as turning pumps on and off or activating other control functions based on the internal program within the Neon data logger/ RTU.
  • The Neon system has fully bi-directional communications between the Neon data logger/ RTU units and the central Neon server.
  • This allows for remote diagnosis, remote programming and remote firmware updating for the operation of the remote equipment and thereby reducing costly site visits.

PHYSICAL SPECIFICATIONS 

Material Powder Coated Aluminium Enclosure
Size 282mm x 122mm x 40mm (LxWxH), 650g
Operating temperature -20°C to 60°C. Not affected by humidity
Antenna Model dependent, external stub/whip/satellite antenna

INTEGRATED LOGGER SPECIFICATIONS 

Storage memory 7.5Mbytes Flash (non-volatile), 3.75 Million log data points
Memory expansion SD card, micro size, 32Gbyte maximum capacity, 16 Billion log data points
Scan rate Programmable from 1 second to 5 minutes
 
Log rate Programmable from 1 second to 24 hours
Time clock Battery Backed Real Time Clock (RTC),
Accuracy +/- 10 seconds/month (non- Neon version),
locked to server time clock (Neon version)
CPU 16 Bit, 20MHz, Ultra-Low Power